For detailed information, other images and documents, please select individual articles from the following table.

TESA TECHNOLOGY Workshop callipers, vernier scale, without blade tips
without blade tips, without fine adjustment
You need more information or have not found your desired product?
Products
You need more information or have not found your desired product?
Call customer service: +49 (0) 7141 498-4848
Application
For measuring external and internal dimensions.
Execution
- Stainless hardened steel
- Matt chrome-plated scale
- Error limits for vernier scale 0.02 mm:
Length 0-250 mm: ± 30 µm
Length 250-400 mm: ± 40 µm
Length 400-500 mm: ± 50 µm - Error limits for vernier scale 0.05 mm:
Length 0-300 mm: ± 50 µm
Length 300-400 mm: ± 60 µm
Length 400-500 mm: ± 70 µm
Advantage
- Main scale is slightly recessed to prevent wear
- Smooth, even guidance of the slide
Delivery
In case
Select RAL-colour code
!! NOTE: On-screen visualisation of the colour differs from real colour shade!!